Product classification
Infrared Dewar Vacuum Exhaust Station
Characteristics of the equipment
The equipment is mainly used for the vacuum treatment of infrared dewar. It is an oil-free, ultra-high vacuum system, which can realize the control of the preparation process such as infrared dewar internal vacuum acquisition, baking degassing, working gas protection, air tightness detection, etc. It has the characteristics of fast exhaust speed and high ultimate vacuum degree. The equipment is widely used in infrared detection, aviation, aerospace and other military industries and civil fields.
Technical performance
1 The number of stations is 16 stations, divided into two groups, each group has 8 stations;
2. Ultimate vacuum degree: the vacuum degree in the hot state is 5~7×10-7Pa in the no-load state;
Heating temperature of 3 station is 80℃, temperature uniformity of 8 channels is ±1℃, temperature control accuracy is ±1℃;
4. The N2 filling interface is configured at the working station, so that the N2 protection can be filled when the workpiece is unloaded;
5. The special leak detection port can meet the requirement of careful helium mass spectrometry leak detection after the installation of the workpiece each time, so as to avoid the exhaust process in the state of air leakage
Links
Contact us
KYVAC Technology Co., Ltd.
Contact number:010-61778196
Project communication:18611455296
Customer service:18611455375
Complaints Hotline:18611455295
Shop phone:010-82548098
Suzhou Kemei:18611455368
Contact email:kyvac@kyky.com.cn
Contact address:No.13, North ertiao, Zhongguancun, Haidian District, Beijing
Official account
Website
COPYRIGHT © Beijing Zhongke Kemei Technology Co., Ltd 京ICP备2020044440号-1 Website map